Replace an RPIC in a duplex chassis
Last Updated:
June 30, 2026
- Be sure you are wearing an ESD strap when handling the RPIC.
- If you have made any changes to the E6000 CER configuration since the last write memory command was entered, run the write memory command again.
- Back up the existing configuration of the RSM by performing the following steps:
- Enter copy running-config BKUPMMDDYY.cfg
- Use Secure FTP (SFTP) or FTP to transfer the backed-up configuration from the E6000 CER to another system (your PC, for example).
The system produces the following output: Backup completed successfully. - Ensure that the RSM is in the same slot as the RPIC to be replaced and is in the Standby Duplex State. An active RSM will have all three LEDs green; a standby only has the Power and Status LEDs lit. Status can also be determined by using the show linecard status command.
Refer to the following example output for the status of the RSM:
show linecard statusSample Output:
Chassis Type: E6000 Slot Description Admin Oper Duplex Serial HW Version Prov/Det Admin UP/ State State State Number Type Allowed ports Chassis Type: E6000 Slot Description Admin Oper Duplex Serial HW Version Prov/Det State State State Number Type 0 UCAM Spare Up IS Standby 13243CUP0026 UCAM-24096W/C05 UCAM/UCAM 1 UCAM Up IS Active 12423CUP0017 UCAM-24096W/C04 UCAM/UCAM 6 RSM A Up IS Active 14443RSM0222 RSM-08241W/D04 RSM/RSM 7 RSM B Up IS Standby 15233RSM0032 RSM-08241W/D06 RSM/RSM 12 DCAM-B Up IS Active 15193CDN0036 DCAM-08256W/D10 DCAM/DCAM 13 DCAM-B Spare Up IS Standby 14303CDN0198 DCAM-08256W/D07 DCAM/DCAM - Switch sides if the desired RSM is not standby. After the soft-switch is made, the RPIC behind the standby or out-of-service RSM can be replaced (you do not have to wait for the RSM to go standby). If the desired RSM is already standby, its RPIC can be replaced immediately.
- Perform a soft-switch to switch the active pair over to standby, enter: configure reset soft-switchIf you are using telnet to access the E6000 CER, the telnet session is disconnected during the soft-switch and requires you to telnet back in.
- Remove the serial and admin Ethernet cables attached to the standby RPIC, if there are any.NOTE: We recommend that you label any cables that you disconnect so you can easily restore them to the same place.
- Unplug the standby RPIC card and plug in the replacement RPIC.NOTE: The standby RSM is reset during this procedure and does not return to service until the replacement RPIC is inserted and detected.
- Allow the E6000 CER to return to duplex and confirm by executing the show linecard status command. The standby RSM will display IS Standby.