During a session, certain preferences are preserved as you navigate between applications inside ServAssure NXT.

Common preferences preserved for all applications

Many actions are common across all the applications of ServAssure NXT. The actions in the following table are preserved in all the applications.

User interface elementSaved actions or display
Search resultsCurrent search result selection
Check boxAll check box selections, including Gear menu items
Radio buttonsAll radio button selections, including Gear menu items
Drop down listsSelected element
TablesTable customizations
  • Column show/hide
  • Sort selections
  • Column width
Hierarchical tree and table expansion (such as Top Alarms)Expanded levels and last location
NOTE: Analyze Network View has a slight variation of this behavior. See Analyze Network View for details.
Chevron expansionExpanded/collapsed state
Gather Selected designationSelected rows retain position at the top of the table
HistoricalSelected graphs (where applicable)

Strum and Zoom selections

Deep links ( the “Back to …” link ) and clicking on an application icon the left pane
  • Open tabs, selections, tab order, graph selections, options are preserved and restored.
  • For Analyze Modem View and PreEQ, fetching of initial data for the modem is preserved.
“Open In…” links Open tabs, selections, tab order, graph selections, options are preserved and restored.
NOTE: Data will contain the context of the current selection, not the state when last in that application.

Alarm Central

In addition to the general preferences, some user selections are preserved when you when you navigate away from Alarm Central and return.

NOTE: Clicking the Alarm Central icon, , now returns you to your last state, and not the Top Alarms view. Access the Top Alarms view at any time by clicking the head of the navigation bread crumb.
Alarm Central view with the head of the navigation breadcrumb circled.
The following table details the user selections that are preserved:
Table 1. Tab-specific actions for Local View
TabSaved actions or display
GeneralExpand/Collapse state of the left panel

Width of the left panel

MapAll option selections, including all RF Stats

Draw to select selection

Show Downstream direction selection

LogicalAll option selections including all RF Stats

Draw to select selection

Show Downstream direction selection

Change View Orientation selection

Set View Layout selection

SpectrumFill-in boxes for:
  • Start Frequency
  • End Frequency
  • Target Resolution

Selected cable modems

PreEQSelected frequency

The following table details data-driven selections that are preserved when you navigate away from Alarm Central and return.

Table 2. Data-driven selections
TabSaved actions or display
GeneralScan being viewed

Position of the timeline slider

Timeline state (expanded/collapsed)

AlarmsSelected and expanded rows

Scroll to last position

Cable ModemsSelected rows
TreeSelected and expanded rows

Scroll to last position

MapSpecial selections
LogicalSpecial selections
SC-QAMSelected rows
OFDM/ASelected rows
AmplifiersSelected rows
HistoricalSpecial selected series
PreEQFetched data

Analyze Modem View

In Analyze Modem View, all preserved user-driven actions are discussed in Common preferences preserved for all applications.

The following table details data-driven selections that are preserved when you navigate away from Analyze Modem View and return.

Table 3. Data-driven selections
TabSaved actions or display
OFDM/AExpanded row

IUC/ Profile tab selection

Sub-CarrierChannel selection in graph

Analyze Network View

In Analyze Network View, all preserved user-driven actions are discussed in Common preferences preserved for all applications.

The following table details data-driven selections that are preserved when you navigate away from Analyze Network View and return.

Table 4. Data-driven selections
TabSaved actions or display
Hierarchy expansionOnly the last-expanded hierarchy element (that was in view) is preserved. The expand and collapse of all levels is not preserved.
Topology SetsThe selected topology set
HistoricalSpecial selections

Filtered series

Upstream Spectrum Analyzer

In addition to the general preferences, the following table details the user selections that are preserved when you navigate away from Upstream Spectrum Analyzer and return.

Table 5. User-driven selections
TabSaved actions
SessionsAll common table customizations
CaptureAll drop-down and fill-ins in the Capture control area
TestAll drop-down and fill-ins in the Capture control area, excluding X-Axis and Y-Axis

The following table details data-driven selections that are preserved when you navigate away from Upstream Spectrum Analyzer and return.

Table 6. Data-driven selections
TabSaved actions
GeneralThe currently selected upstream channel
SessionsFiltered list display
CaptureMarker values. Markers for standard mode and compatibility mode are maintained independently.
TestAll drop-down and fill-ins in the Capture control area, excluding X-Axis and Y-Axis

No Spectrum Analyzer data is retained when you navigate away from this application.