July 07, 2026

Use this procedure to load the selected poll definitions into the SDM database.
- Download the poll library from the ARRIS Support site.
- Place the poll library on a CD or on a networked PC that is accessible from the SDM server.
- Copy the poll library files to the /tmp directory on the SDM, and unzip the contents. (See File copy methods for assistance).
- Change to the snmp
directory by typing cd
/home/sdm/data/external_poll/snmp
This directory contains subdirectories with names based on the device type, version, and so on.
NOTE: If the poll library is the very first revision for a device type, the directory path is created with using a naming convention that includes the device type and version number (for example,/APEX/1.1.0). If there are multiple poll libraries for the same version, you can create the subdirectories with any meaningful name.
- Copy the files from /tmp to /home/sdm/data/external_poll/snmp/<subdirectory name for this poll library - if any>.
- Click Scan.
- Verify that the files are readable.
- Log on to the SDM.
- Select Performance > External SNMP Polls from the main menu bar.
- Click Add Poll. A table is displayed in the window. Each row in the table provides information relevant to a poll in a poll library. For example: Poll Group Name, Revision, Device Type, Model, Object Type, and Released Date.
- Click Check All.
- Select a row and click
Execute to add the poll to the SDM
database. The External SNMP Poll Load page is displayed.