Manual capture (compatibility mode only)
Last Updated:
July 07, 2026
Manual capture allows you to customize your capture settings. To perform a manual capture:
- Open the US Spectrum Analyzer application; see Access upstream spectrum analyzer.
- Enter a CMTS name and channel
string in the format like:
<CMTS name>@<channel string>. You can also select an item from Search History as described in Search channel. - Select Compatibility from the Mode drop-down menu.
- Select Manual from the Analysis drop-down.
- Select a capture Type:
- Fullband. If you select this value, you must select Frequency as your Domain value.
- Passband. If you select this value, you can select Frequency or Time as your Domain value.
Refer to Type for definitions. - Select a value for IUC. Refer to Interval Usage Code (IUC) for options.
- Select a Service Identifier. Refer to Service Identifier for options.
- Select a Domain
option:
- Frequency. This option is available if your Type value is Fullband or Passband. If you select this value, you can also select values for Marker Width and one or more markers.
- Time. This option is available if your Type value is Passband.
Refer to Domain for option definitions. - If your Domain value is Frequency, set a Marker Width value.
- If your Domain value is Frequency you can optionally set markers, as described in Set markers.
- Specify a value for Sample Count as described in Domain.
- Specify a value for Capture Interval as described in Domain.
- Optionally, you can specify a custom range for the X and Y axes, as described in Set up X and Y axes.
- Press Play to start the capture.
- Extend analysis time if needed. See Extending analysis time.