Upstream SCTE 55-1 Out of Band messaging requires upstream MAC cells be forwarded to the VUE using UEPI streams. The VUE de-encapsulates the upstream data, and forwards ARPD datagrams to a Network Controller, such as the NC1500.
The VUE configures one or more RPDs/RMDs to act as a single upstream path associated with a Virtual ARPD. The RPDs are configured with a Source ID, RF port ID and Demod ID of the virtual ARPD. Multiple RPDs/RMDs with the same Source ID are located within the same virtual ARPD where a subset of these RPDs/RMDs can be provisioned with different RF ports. RPDs/RMDs provisioned with the same RF port and Source ID act as a single upstream path and must be assigned the same set of demods and frequencies.
Follow the steps in this task to create a Virtual ARPD for de-encapsulating upstream SCTE 55-1 UEPI streams from RPDs/RMDs.

to configure the VARPD upstream TS.
) to the right of the VARPD entry and select