| Input
Stream High Bit Rate | This alarm indicates that an input stream bit rate has exceeded its
maxBitRate value. Supported values are 'OK' and 'Major.' The alarm will
clear when no input streams are exceeding their maxBitRate
value. |
| Loss Of
Input Stream | This alarm indicates loss of one or more input streams to a mapping.
Supported values are 'OK' and 'Major'. The error will clear when no
input stream loss is detected. |
| Output
Overflow | The alarm indicates that a transport stream is in an overflow
condition and that packets are being dropped. Supported values are 'OK'
and 'Critical.' |
| PID Route
Failure | The alarm indicates a PID remapping failed on one or more transport
streams with PID Mappings applied. Supported values are 'OK' and
'Major.' |
| Program In
Error | This alarm indicates that a program is in error for a mapping due to
the loss of PAT/PMT for the input stream being missing. Supported values
are 'OK' and 'Major'. The error will clear when no service errors are
detected. |