Back to Articles

The table below lists the alarms sent by VUE that are processed and managed by VTM:

Table 1. VUE Syslog alarm notifications
TypeCategoryConditionSeverityDescriptionNotes
AlarmServerLoss of Physical Interface AlarmCritical, MajorDetected a loss of an interface

Reported per interface

Critical Severity if VUE server is NOT part of an RC, Major severity if is.

AlarmTSLoss of Input Stream AlarmMajorDetected loss of an input streamReported per server
AlarmTSInput Stream High Bit Rate AlarmMajorDetected an input stream exceeded maxBitRate valueReported per server
AlarmTSProgram in Error AlarmMajorDetected an output stream is in error (e.g. missing PAT/PMT)Reported per server
AlarmTSOutput Overflow AlarmMajorDetected an overflow condition for an output streamReported per server
AlarmHALoss of Heartbeat AlarmWarningDetected failure to receive heartbeatsReported per server
AlarmHALoss of Heartbeat Interface AlarmMajorDetected interface failure where heartbeats are receivedReported per server
AlarmHAIngress Rate ComparisonMajorDetected ingress rate of active node is below standby's rateReported per server
AlarmHAIngress Below Threshold AlarmMajorDetected ingress rate is below configurable thresholdReported per server
AlarmHAHA Not Available AlarmMajorDetected a failure of standby causing HA to be disabledReported per server
AlarmServerServer Communication Error AlarmMajorDetected a failure to communicate to a VUE serverReported per server
AlarmServerMissing Time SourceWarningDetected the VUE Server is not synchronized to a PTP or NTP time sourceReported per server
EventTSBuffer Reset Error EventInformationalReported when internal pipe buffer is reset due to underrun or overflowReported per server
AlarmRxDPending RxD InitializationWarningDetected one or more RxDs in the process of initializingReported per ACCP
AlarmRxDChannel Configuration ErrorMajorDetected RxD with one or more channels in a configuration error stateReported per RxD
AlarmRxDDropped Egress Packets ErrorsMajorDetected RxD with one or more channelsReported per RxD
AlarmRxDOut of Sequence Packets ErrorWarningDetected RxD with one or more channels experiencing dropped out of sequence DEPI packets above configured thresholdReported per RxD
EventServerServer RestartedInformationalVUE server restartedReported per server
EventServerACCP RestartedInformationalACCP on a VUE server restartedReported per ACCP