Back to Articles

The Auto Failback feature enables an N:1 (hot_cold) RC to automatically transition from an Active Standby back to the Initially Active server after the Initial Active server becomes available and healthy again. Auto Failback is disabled by default. You can also set the Auto Failback Delay parameter to control the time period in seconds, to wait before auto-failing back once the active server has been recovered. The value is an integer from 1 to 600. The default Auto Failback Delay value is 60 seconds.

You may also edit the existing RC to enable the auto failback feature.

  1. Select Elements > VUE in the navigation bar.
  2. Select a VUE system from the list which is a member of the RC.
  3. Select the RC-Server tab.
  4. Select the desired Hot:Cold cluster on which you want to apply the autofail back feature.
  5. Click the (Menu) button.
    The menu options appear.
  6. Click Suspend.
    Click Yes to confirm the suspension.
  7. Click the (Menu) button.
    The menu options appear.
  8. Select Edit.
  9. Select the Auto Failback Enable checkbox.
  10. If desired, change the Auto Failback Delay in seconds. The default value is 60 seconds.
  11. Click Save to confirm the changes.